The problem

What we found

This highly engineered, concrete-heavy home was built on a section of properly compacted road mix and supported by large, deep columns. Despite robust construction, early signs of settlement appeared. The homeowner also noticed movement around a built-in negative-edge pool. With heavy structural loads and premium finishes, early intervention was important to protect the investment.

The solution

How we repaired it

We created access points through the driveway and other areas to reach the deep structural columns. Using a drill rig and pilot holes, we advanced steel injection tubes to approximately 20 to 22 feet and injected high-density structural polyurethane foam around the columns to improve the surrounding soil's load-bearing capacity. At the same time, a second crew stabilized the pool perimeter with deep injections around the pool edges. Where needed, we also drilled through the pool bottom to fill voids and obtain as much lift as possible.

Explore Soil Stabilization
The result

What changed

The columns and pool were stabilized, reducing the risk of continued settlement. While the pool did not achieve full lift to the original target, it received enough lift and reinforcement to confirm stabilization and restore confidence in performance.

Have a similar problem?

Let us test what is underneath.

We inspect the site and measure the soil before recommending a repair.

More project experience

Recent case studies

See all projects →
technicians working beside the concrete dam excavation (image 1)
Soil StabilizationMarsing, Idaho

Erosion Around a Concrete Dam

A homeowner built a concrete dam in a creek to create a pond for irrigation storage. During backfill, boulders and road mix were placed around the structure. Once the pond fi…

Read the project
grain-silo concrete crack and pressure-grouting work (image 1)
Crack and Joint SealingHomedale, Idaho

Grain Silo Waterproofing

Cracks at the base of grain bins were allowing water to enter the silo, causing grain rot and financial loss. Previous attempts using surface sealants and even spray foam coa…

Read the project
pump-house slab edge and exposed voided subbase (image 1)
Crack and Joint SealingEagle, Idaho

Cistron Water Leak Repair

This site presented two related issues. Water was leaking around the main pipe entering the cistern, escaping through concrete at the penetration. Over time, the leak caused…

Read the project